• OLFACTOMETERS

    TO DETECT AND MEASURE ODOR DILUTION

in-field odour measuring device, detect, measure odor, olfactometer. ambient odour, indistrual odour, agriculture odour,

Scentroid Infield Olfactometer – SM100

Ultra-Portable Field Olfactometer

Scentroid SM100 is the world’s first field olfactometer. This in-field odour measurement apparatus allows users to accurately quantify ambient odour strength.

This revolutionary odour measurement device (Patent Pending) offers an easy-to-use and cost-effective alternative to guessing at odour strength or using expensive odour measuring laboratories.

Application
  • Conduct daily odour emissions monitoring of industrial operation
  • Determine odour source contributions
  • Evaluate odour emission impact on neighbouring residents
  • Determine odour mitigation effectiveness over time
  • Monitor emission compliance
  • Verify lab results and dispersion model predictions
  • Conduct Panelist Screening
Basics of Operation
  1. The SM100 field odour measurement draws a sample of ambient air via venture vacuum pump and dilutes it using fresh odourless air from a high pressure compressed air tank.
  2. Operator uses an adjustable sliding valve to control the ratio of fresh to ambient air.
  3. The mixed air is sent to through a flexible hose to a disposable face mask.
  4. Operator slowly increases concentration of the mix until the odour of ambient air is detected.
  5. A scale on the sliding valve shows the Dilution to Threshold ratio or odour intensit
Capabilities
  • Use of field olfactometer
  • Ultra-portable, weighing only 4 lbs.
  • Measure odors as low as 2 OUs and as high as 30,000 OUs
  • Comparable results to lab based olfactometers.
  • Simple and cost effective
  • Capable of conducting panel screening using n-butanol.
Technical specifications
Air Supply Capacity(min) 15 min
Dilution range (Ou/m3) 2 – 30,000 (2^15) Download Calibration sheet for more information.
Dilution Principle Stainless Steel Eductor
Number of Dilution Steps: 15 (adjustable range)
Pres. Flow Rate (l/min) 20
Presentation Face Velocity (m/s) 0.3
Face Mask Half-face PTFE
Wetted Material Stainless Steel and PTFE
Tank Pressure (PSI) 4500
Dimensions (in) 16x6x6
Weight Kg/(lb) 3.5 (8)
Power Requirements: None
in-field odour measuring device, detect, measure odor, olfactometer. ambient odour, indistrual odour, agriculture odour,

INTELLIGENT PERSONAL OLFACTOMETER – SM100i

Scentroid SM100i , Intelligent Personal Olfactometer represents the next evolution in personal olfactometry

The Scentroid SM100i , Intelligent Personal Olfactometer represents the next evolution in personal olfactometry. This automated olfactometer can conduct full odour analysis including YES/NO and Hedonic Tone test modes in full accordance to the international EN13725 standard.

Application
  • Conduct daily odour emissions monitoring of industrial operation
  • Determine odour source contributions
  • Evaluate odour emission impact on neighbouring residents
  • Determine odour mitigation effectiveness over time
  • Monitor emission compliance
  • Verify lab results and dispersion model predictions
  • Conduct Panelist Screening
Basics of Operation

The SM100i , Intelligent Personal Olfactometer draws the sample  via eductor (venturi pump) and dilutes it using fresh odour less air from a compressed air tank. A micro-controller adjusts the dilution ratio and interacts with the panelist though a touch screen tablet to conduct YES/NO test mode and automatically calculates the odour concentration. The results can be viewed on google earth or exported as an excel file for further analysis.

Capabilities
  • Ambient air without any additional sampling equipment
  • Directly from smoke stacks or filter inlets
  •  Directly from flux chambers or wind tunnels
  • Air samples stored in sampling bags
  •  Screen Panellist using N-butanol and YES/NO method in full accordance to EN13725.
Technical Specification
Manufacturer IDES CANADA INC
Model SM100i
Air Supply Capacity 20 Min base / 40 Min with dual air tank option
Number of samples per tank refill 10-15
Dilution range 2 – 11,000
Dilution principle Stainless Steel Eductor
Number of dilution steps 15 (adjustable range)
Selectable ranges 2-101; 4-678; 44-656; 2-3600; 2000-30,000
Interface with mobile device Bluetooth
Battery Rechargeable Lithium-ion  with 36 hour capacity per charge
Presentation device for direct olfactometry (In-Field) Half-face PTFE mask
Presentation device for delayed olfactometry (In-Lab) PTFE coated Sniffing Port
Wetted Material Stainless steel and PTFE
mobile olfactometer, odour measurement, detect, measure odor, olfactometer. ambient odour, indistrual odour, agriculture odour,

SC300, PORTABLE OLFACTOMETER

Scentroid SC300 is the world’s most advanced mobile olfactometer

Scentroid SC300 is the world’s most advanced mobile olfactometer. It is capable of odour measurement and analysis to all international olfactometry standards: EN13725:2003, ASTM E679-04, NVN2820, VDI 3881, GB/T14675-93. Best of all, it can be transported to site and deployed in minutes for a complete accredited olfactometric laboratory.

Application
  • Conduct on site odour measurement
  • Determine Odour Concentration in OU/m3 per EN13725 Standard
  • Conduct Hedonic Tone assessment of odour emissions
  • Conduct panelist training and N-butanol screening
  • Determine odour Concentration in accordance to Chinese and Japanese standard (GB/T14675-93)
  • Employ Binary, Triangular, Yes/No, and direct presentation methods
  • Only Olfactometer capable of odour assessment from Petrochemical, oil refineries, and agricultural sources due to unparalleled contamination control technologies employed
Basics of Operation

Deployment simply requires connecting the power cord to a standard 120/240 VAC outlet and connecting the pneumatic hose between the air supply sub-system and the Control Sub-system. The air sub-system provides clean air regardless of ambient air through its incorporated oil-free pump, HEPA Filter, carbon filter, no-maintenance membrane air dryer, and regulator.

Capabilities
  • Panelist Screening using N-butanol
  • Automated Binary Test mode
  •  Automated Triangular Test Mode ( with 3 ports)
  • Automated YES/NO Mode
  •  Automated Hedonic Tone to the VDI standard
  •  Self Calibration using CO gas
  •  Portable air supply unit
Technical Specification
Model SC300
Testing Modes Triangular Forced Choice, Binary Forced Choice, Direct Presentation, Hedonic Tone, GB Source, and GB boundary
Dilution Principle Venturi Eductor
Control Mechanism Mass flow controllers on both clean air and sample air intake
Dilution Range 2^3 to 2^17 optional range extension
Dilution Steps Variable
Accuracy Error less than %5
Pres. Flow Rate Variable: 5 lpm to 30 lpm
Presentation Velocity 0.25 m/s at 20lpm
Response time 0.2 sec
Sample Delivery Adjustable
Control Siemens PLC
Computer Interface Ethernet Network/USB
Display and Interface Siemens industrial 8” full-color touch-screen Admin and separate industrial 5″ for panelist
Data Processing Test data including end-criteria and statistics processed through PLC
multi-sensory olfactometer,odour measurementmobile olfactometer, odour measurement, detect, measure odor, olfactometer. ambient odour, indistrual odour, agriculture odour,

SC300-P, SCIENTIFIC OLFACTOMETER WITH EEG CAPABILITIES

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities

Scentroid SC300-P (Scientific Olfactometer) is a specialized multi-sensory olfactometer with EEG and FNIR capabilities for advance psychological and physiological research and treatment. The SC300-P has been used by researchers and doctors to research and treat a variety of disorders including Post Traumatic Stress disorder.

Application
  • Olfactory Sensitivity testing
  • PTSD study and treatment
  • Multi-sensory psychological study
  • Diagnostic and treatment of olfactory disorders
  • Product testing and market research
Basics of Operation
  • Clean air is supplied by the portable Air Supply Module
  • Up to 8 samples are connected to the sample ports and prepared for presentation
  • Panelists are fitted with EEG cap and the system is set to record response
  • A test mode is selected and audio and visual data loaded for presentation
  • The SC300P will present olfactory, audio, and video stimuli in accordance to the defined test mode
  • At each presentation, the SC300P will trigger the EEG with identification of the audio, video and olfactory stimuli presented allowing easy analysis of subject’s response
Capabilities

he SC300-P (Scientific Olfactometer with EEG Capabilities) is more than just an olfactometer, but a true multisensory stimuli instrument. Up to 8 odours can be connected to the instrument and programmed to be administered to the panellist at various concentrations. Images, videos, and audio stimuli can be simultaneously administered by the SC300-P (Scientific Olfactometer with EEG Capabilities) via its external monitor to provide a complete sensory immersion.

EEG, FNIR, AND EPRIME CONNECTIVITY

The SC300-P (Scientific Olfactometer with EEG Capabilities) seamlessly integrates with EEG and FNIR machines to provide simultaneous stimuli reading from the panellists. Trigger signals will provide clear reference on which stimuli was being administered. EPrime connectivity allows the SC300-P to act as master or as part of a large network of instruments in a comprehensive study.

Technical Specification
Model SC300-P
Testing Modes Sensitivity analysis, Audio/Olfactory pulse presentation, Psychological video/olfactory analysis, custom audio/olfactory/ image test mode.
Visual Interface Large 32” touch screen and Siemens industrial 6” touch screen for sensitivity analysis
Audio Interface Built in speakers with Dolby digital surround sound
Olfactory Interface Choice of sniffing port or half-face disposable masks
Dilution Steps Variable
Number of simultaneous odour presentations 4 upgradable to 8
Pres. Flow Rate Variable: 5 lpm to 30 lpm
EEG interface RS232
FNIR interface RS232
EPrime interface RS232. USB, Ethernet optional
Control Hardware Siemens industrial real time controller
Test Administrator interface Siemens industrial 8” full color touch-screen
Display Language English, Chinese, French, German, Turkish and Spanish
stationary olfactometer, olfactometer, odour measuring, industrial smell, agricultural smeel

SS600, LABORATORY OLFACTOMETER

Scentroid SS600 is the world’s most advanced stationary, dynamic, and fully automated olfactometer.

Scentroid SS600 is the world’s most advanced stationary, dynamic, and fully automated olfactometer. It is capable of odour measurement and analysis to all international olfactometery standards: EN13725:2003, ASTM E679-04, NVN2820, VDI 3881, GB/T14675-93, AS 4323.3

Application
  • Determine Odour Concentration in OU/m3 per EN13725 Standard
  • Conduct Hedonic Tone assessment of odour emissions
  • Conduct panellist training and N-butanol screening
  • Determine odour Concentration in accordance to Chinese and Japanese standard (GB/T14675-93)
  • Employ Binary, Triangular, Yes/No, and direct presentation methods
  • Only Olfactometer capable of odour assessment from Petrochemical, oil refineries, and agricultural sources due to unparalleled contamination control technologies employed
Basics of Operation
  • Select the desired Test mode
  • Select the panelist from the data base or scan their badge bar code
  • Scan the bar code of the sample ID or enter it manually
  • Select start
  • SS600 will automatically go through a comprehensive purging and stabilization routine
  • All panelist data is automatically processed in real time and the odour concentration is provided to the administrator at the end of the test
International Standard Compliance
  • VDI 3881
  • AS 4323.3
  • NVN2820
  • GB/T14675-93
  • EN13725:2003
  • ASTM E679-04
Technical Specification
Manufacturer IDES Canada Inc
Model SCENTROID – SS600 Six Station Dynamic Dilution Olfactometer
Testing Modes Triangular Forced, Binary Forced,  Yes/No,  Direct Presentation,  Hedonic Tone, GB Boundary, and GB Test
Dilution Principle Venturi vacuum pump Uses no moving parts to create vacuum and draw out the sample air.
Control Mechanism of volumetric flow Mass flow controllers on both clean air and sample air intake Industry first olfactometer to use full feedback to guarantee accurate dynamic dilution level
Dilution Range 2 to 2^16 Optional 2 to 2^24 Available
Dilution Steps Selectable Unlimited steps between 2 and 2^16
Accuracy error < 2% reading
Presentation Flow Rate Variable: 15 lpm to 30 lpm Dynamic MFC based feedback control allows variable presentation flow rate
Presentation Face Velocity 0.25 m/s at 20-lpm
Response time 0.2 s
Settling Time <1s
Sample Delivery (Sniffing) Time Adjustable
Required Sample Volume Depends on test conditions selected. Average 6-panelist test consumes 2-liters by using a 10-second sniff time at 20-lpm Minimized through use of switching valve at sample intake port to allow fresh air through while system stabilizes and waits for panelists
Calibration Full feedback design does not require re-calibration
Control Siemens PLC PLC driven for fully automated process. Does not require a computer to operate
Computer Interface Ethernet Network/USB USB is used for data transfer.Ethernet connectivity allows it to be seen by any computer on the network.
Display and Interface Siemens industrial 8” full color touch-screen for administrator and Six of Siemens 6″ industrial touch screen for panelists Test Results, parameters, and system information displayed on the Admin screen.Panelist input selection, data entry, buttons, messages, warnings, and all other information is displayed through the panelist touch screen
Data Processing Test data including end-criteria and statistics processed through PLC.Collected data formatted and presented as coma-separated to be used in excel or other post data processing software USB mass storage device support for extraction and storage of data on any standard flash disk or USB HDD
Display Languages Selectable: English, Italian, French, German, Spanish, Chinese All test including Panelist input selection, data entry, buttons, messages, warnings, and all other information displayed
Presentation Device Stainless Steel Sniffing Ports
Tubing Material Stainless Steel (316L Electropolished)
Wetted Surfaces on MFCs and valves Stainless Steel (316L)
Table Material All Stainless steel construction to eliminate contamination
Dimensions L x W x H (cm)
Weight 120 Kg
Air Supply Oil-free compressor with water separator, micro-mist separator, maintenance free drier and carbon filter enclosed in sound absorbing foam.
Power Requirements 110VAC, 60Hz, 10 Amps or 220VAC/50Hz, 10 Amps
Standards EN13725:2003,  ASTM E679-04,  AS 4323.3,  NVN2820,  VDI 3881,  GB/T14675-93 Exceeds all International Standards for olfactometry
Station Portable Olfactometer olfactometer, odour measuring, industrial smell, agricultural smell

SS400 PORTABLE 6 STATION OLFACTOMETER

Scentroid SS400 olfactometer is an advance mobile 6 station portable olfactometer. The Six Station Portable Olfactometer SS400 is used to assess odour concentration from a sample using 2 presentation modes (Binary or Yes/No) by fulfilling the requirements of the EN13725 and VDI 3881 standards.

Application
  • Measure odour concentration in OU/m3
  • Assess hedonic tone according to VDI standard
  • Conduct binary and yes/no method
  • Follow all odour standards such as EN13725
  • Conduct panelist screening using n-butanol
  • Interface to Scentroid Laboratory Management Software
Basics of Operation
  • Connect odour sample bag to the SS400 Six Station Portable Olfactometer
  • Using the Admin tablet start a new test
  • Scan the unique barcode on the sample
  • Select the number of panelist (1-6) and the test type (Yes/No, Binary, or Hedonic Tone)
  • System will conduct purging and assessment automatically
  • Panelist will be instructed to sniff and input their reponse using their dedicated tablets
  • System will log and send all results wirelessly to Scentroid’s Laboratory management software
Capabilities

The Scentroid SS400 Six Station Portable Olfactometer is the world’s only portable six (6) panel olfactometer. The compact and flexible form allows for easy transportation and deplyment. The flexible  connection between panelist stations and the central control pyramid allows the SS400 Six Station Portable Olfactometer to be setup to fit the table and room layout. Full automation and data processing using Scentroid’s Laboratory Information Management software allow any laboratory to be easily certified to ISO17025.

  • Portable and easy to deploy
  • Full automation
  • assessment using 1 to 6 panelist
  • automated purging using oxidation (optional)
  • Built in Photo Ionization Detector for analysis of VOCs  and dilution verification
Technical Specification
Model Scentroid SS400 Six Station Portable Olfactometer
Number of Panelists From1 up to 6 panelists
Test Modes Binary, Yes/No, Hedonic Tone (VDI), Intensity
Dilution Principle Fixed orifice jet pump with Stainless Steel educator
Dilution Steps 15
Dilution Range 2^2 to 2^16
Accuracy Error less than 5%
Presentation flow rate 20 lpm
Sample Analysis Time 7 samples/hour (8 min)
Sample Consumption Less than 10L for 3 rounds with 5 dilution steps and 10 second sniffing time.
Panelist Control Touch Screen Interface
Administrator Display 10” smart tablet touch screen
Communication WiFi and Bluetooth®
Display language English
Presentation 2 Stainless Steel Sniffing Ports per Station
Body Stainless Steel
Software upgrade Automatic over Wi-Fi
Dimensions 63.5 x 63.5 x 31 cm
Standards EN13725/2003, ASTM E679-04, VDI3881, AS4323.3
Weight 30 kg olfactometer and 35 kg air supply module

Request a Quote